Cobra Ridge Vent
Hello, I recently had a roofer install a ridge vent on my house, and he chose the Cobra ridge vent. After taking a close look at the result, both from the attic and the roof, I am concerned that there is virtually no gap that would allow for reasonable air flow. Does anyone have experience with this product? Thanks. Steve Originally Posted by skirincich Hello, I recently had a roofer install a ridge vent on my house, and he chose the Cobra ridge vent. After taking a close look at the result, both from the attic and the roof, I am concerned that there is virtually no gap that would allow for reasonable air flow. Does anyone have experience with this product? Thanks. Steve hi Cobra vents and other types of mesh ridge vents are also known to commonly fail by their poor design. Dust and debris too easily clogs the mesh and the vent becomes quickly useless. But a different type of ridge venting system other than Coabra vent is a better long term solution. The primary problem with some ridge vents is their lack of an external baffle. The metal ridge vents usually have this. I personally cannot recall ever having seen on without external baffles. The baffles are the little up-turned lip at the bottom of the vents. How an externally baffled ridge vents works is, as the wind passes over the baffle, it creates low pressure, drawing air from the attic. The faster the wind moves over the baffle, the greater the pressure it creates, inducing more air from the attic. On the other hand, with a vent without an external baffle, as the wind hits it, a possitive pressure is produced, thereby greatly inhibiting the proper air flow. Call the roofer and have them replace it with other type better of ridge vent he did cut a hole for the vent, right? at least a 1 and 1/2 inch strip on both sides? also ridge vent will only work if the soffit or at the very least the gable ends are vented. heat rises! mesh one do clog up with dust after a long while but you have less of a chance of bugs sneaking in. pgtek- what kind of new system do you suggest? i to am looking for answers. how about the cobra vent 11 or the Shingle vent11 from Air vent ? thanks john hi check this http://www.owenscorning.com/around/v...sure_ridge.asp good luck
Related Posts:
Attic ventilation gable vents and ridge vents
Attic Ventilation: Gable Vents and Ridge VentsMy house has a ridge vent and a gable vent - one on each end of the house. It has a low slope roof. I understand this is not the best arrangement for...
Change dryer vent from rear to side
Change dryer vent from rear to side?I have recently (yesterday) purchased a Samsung DV209AEW electric dryer from Lowes. I have it in my house and installed and everything. The problem is that my l...
Desa vent free gas log shutting off
DESA Vent Free Gas Log Shutting OffI have an interesting issue with a DESA natural gas log installed in my home. I don't have any real paperwork on the unit and apparently DESA went out of busines...
Attic fan pros and cons
Attic fan pros and consI have a newly built home (2000) with plenty of soffit vents. But several of my neighbors have added attic fans to supplement ventilation in their attics. They all say their...
Ao smith 50 galon power vent not igniting at all
AO Smith 50 Galon Power Vent not igniting at allMany other owners of these AO Smith power vent water heaters seem to have the problem where the burner will light for a few moments then turn off. I...